Powernice Linear Tracker Test Equipment-Programmable Constant Temperature and Humidity Test Chamber

2022-05-31
Linear tracker test content: 480 hours of cyclic connection to the power supply at high and low temperature (according to customer requirements)
The purpose of the linear tracker test: the actuator adapts to the corresponding operating temperature range
Linear Tracker Test Procedure:
1. Put the actuator into the constant temperature and humidity test box and turn on the power.
2. According to customer requirements, perform high and low temperature cycle test on the actuator.
3. After the test, check whether the product meets the customer's requirements.